Quantitative magnetization transfer imaging made easy with qMTLab: Software for data simulation, analysis, and visualization

@article{Cabana2015QuantitativeMT,
  title={Quantitative magnetization transfer imaging made easy with qMTLab: Software for data simulation, analysis, and visualization},
  author={Jean-François Cabana and Ye Gu and Mathieu Boudreau and Ives R. Levesque and Yaaseen Atchia and John G. Sled and Sridar Narayanan and Douglas L. Arnold and Gilbert Bruce Pike and Julien Cohen-Adad and Tanguy Duval and Manh-Tung Vuong and Nikola Stikov},
  journal={Concepts in Magnetic Resonance Part A},
  year={2015},
  volume={44},
  pages={263-277},
  url={https://api.semanticscholar.org/CorpusID:101097689}
}
Quantitative magnetization transfer imaging (qMTI) increases specificity to macromolecular content in tissue by modeling the exchange process between the liquid and the macromolecular pool. However, its use has been mostly restricted to researchers that have developed these methods, in part due to the need to write complicated in-house software for modeling and data analysis. We have developed a software package (qMTLab) with a simple and easy to use graphical user interface that unifies three… 

Evaluation of Magnetization Transfer Contrast Sequences: Application to Monitor Age-Related Differences in Muscle Macromolecular Fraction

Age-related decreases in MTC may reflect that loss of myofibrillar proteins dominates the increase in collagen content with age, and the modest correlation of MTC indices with T1 indicates that all the age-related differences in MTC cannot be explained by an increase in inflammation.

Optimization of acquisition parameters for cortical inhomogeneous magnetization transfer

The feasibility of high-resolution cortical myelin imaging using ih MT sat in less than 20 minutes is demonstrated and the first group-average ihMT sat whole-brain map at 1 mm isotropic resolution is presented.

Quantitative MRI using STrategically Acquired Gradient Echo (STAGE): optimization for 1.5 T scanners and T1 relaxation map validation

The optimized STAGE protocol can provide accurate and repeatable T1 mapping along with other qualitative images and quantitative maps in about 7 min on 1.5T scanners, and shows good accuracy and repeatability.

Fast calculation software for modified Look-Locker inversion recovery (MOLLI) T1 mapping

The presented software tool (fT1fit) facilitated rapid T1 map and extracellular volume fraction map calculations and the C++ multi-core RD was the fastest method on a regular eight-core personal computer for pre- or post-contrast T1map calculation.

Spin Lattice (T1) and Magnetization Transfer Saturation (MTsat) Imaging to Monitor Age-Related Differences in Skeletal Muscle Tissue

T1 increase with age may reflect increase in inflammatory processes while the decrease in MTsat may indicate that magnetization transfer may also be associated with muscle fiber macromolecules.

Fast and accurate compensation of signal offset for T2 mapping

The new GS T2 mapping algorithm offers a fast and much more accurate off-the-shelf replacement for the inaccurate 2-parameter fit in the vendor’s software.

qMTNet+, an Improved qMTNet with Residual Connection for Accelerated Quantitative Magnetization Transfer Imaging

qMTNet + improves qMTNet, generating qMT parameters from undersampled MT data with higher agreement with ground truth values, and has the potential to accelerate qMT imaging for diagnostic and research purposes.

Formalin Tissue Fixation Biases Myelin-Sensitive MRI

F and MWF are significantly increased by formalin fixation, while D2O-exchanged ZTE intensity is minimally affected; changes in qMT and MWI may be due, in part, to delamination and formation of vacuoles in the myelin sheath.

Quantitative magnetization transfer imaging via selective inversion recovery with short repetition times

A modification of SIR with smaller TR values and a greater signal‐to‐noise ratio (SNR) efficiency is described, which would allow selective inversion recovery to be implemented only with repetition times TR ≫ T1.

Quantitative imaging of magnetization transfer using an inversion recovery sequence

A new imaging method has been developed for quantitatively measuring magnetization transfer (MT). It uses a simple inversion recovery sequence, although one with very short (milliseconds) inversion

Quantitative magnetization transfer imaging using balanced SSFP

Short repetition times in combination with high signal‐to‐noise ratios make bSSFP an ideal candidate for the acquisition of high resolution isotropic quantitative MT maps, as for the human brain, within clinically feasible acquisition times.

Modeling pulsed magnetization transfer

The results of this study demonstrate that the approximations used in pulsed MT modeling are quite robust, and it was shown that the semisolid pool fraction, M0B, which is known to correlate strongly with myelin content, and the transverse relaxation time of macromolecular protons, T2B, could be evaluated with reasonable accuracy regardless of the model used.

Optimized inversion recovery sequences for quantitative T1 and magnetization transfer imaging

New protocols are employed, which vary both ti and td and fit the data with minimal approximations, and provide an improved means for determining T1 and magnetization transfer parameter values compared to previous inversion recovery based methods.

Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI

A novel imaging technique is described that yields all of the observable properties of the binary spin‐bath model for magnetization transfer and is demonstrated for in vivo studies of the human head.

Quantitative interpretation of magnetization transfer in spoiled gradient echo MRI sequences.

From experiments on agar gel, this method is shown to reliably and accurately estimate the exchange and relaxation properties of a material in an imaging context, suggesting the feasibility of using this technique in vivo.

Quantitative imaging of magnetization transfer using multiple selective pulses

The method has been used to make quantitative measurements of macromolecular content in cross‐linked bovine serum albumin and employed in conjunction with echoplanar imaging to produce maps of the spatial distribution of the macromolescular content.

Fast macromolecular proton fraction mapping from a single off‐resonance magnetization transfer measurement

It was demonstrated theoretically and experimentally that accuracy of the single‐point method depends on the offset frequency and flip angle of the saturation pulse, and optimal ranges of these parameters are 4–7 kHz and 600°–900°, respectively.